Net zero home with solar: how big an array do you need?
A net zero home generates as much energy on site over a year as it uses, and in Canada that usually means a very efficient, airtight envelope, a heat pump and a rooftop solar array of roughly 5 to 10 kW. The envelope comes first, because every kilowatt hour not used is a kilowatt hour the panels do not have to make.
Last updated
What is a net zero energy home?
The idea is an annual balance. Across twelve months the home's solar generation equals its energy use, even though on a winter night it still draws from the grid and on a July afternoon it exports. Definitions differ between programmes: some count only heating, cooling, hot water and ventilation, and others add appliances and lighting. Before comparing two homes, check which loads each label counts. The guide to net zero homes in Canada covers the labels, and net zero energy buildings looks at larger structures.
A net zero ready home is built to the same efficiency but leaves out the panels, with the roof and wiring prepared so an array can be added later. The tiers in the building code are explained in net zero ready code tiers.
Why does the building envelope come before solar?
The envelope is the shell of the home: walls, roof, floor, windows and doors. A well-insulated, airtight shell lowers the heating and cooling demand, which shrinks the equipment, the ductwork and the PV system. Panels are an expensive way to cover a load that better wall construction could have removed.
In a new build, the performance of the wall assembly, the windows and the foundation insulation is fixed at construction, and changing it later costs far more than getting it right at the start. Builders often use a thicker wall, continuous exterior insulation or double stud framing to reach the required insulation levels and reduce thermal bridging. Those requirements belong in the design stage, with an energy model that tests each option.
Three parts of it matter most:
- Insulation in the walls, attic and foundation, with attention to thermal bridges such as framing and slab edges.
- Windows and doors with good thermal performance, placed to admit winter sun on the south side.
- Air sealing and a continuous air barrier, so heated air does not leak out through gaps.
Airtightness is measured with a blower door test, which reports air changes per hour at 50 pascals, or ACH50. Typical targets for high-performance homes sit between about 0.6 and 1.5 ACH50, depending on the standard, and conventional new homes are looser. An airtight house needs mechanical ventilation, usually a heat recovery ventilator, to keep indoor air quality up. See air tightness and the blower door test, air sealing a house and the heat recovery ventilator guide for the detail.
How do you size the solar array for a net zero home?
Sizing follows the same logic as any rooftop system, with one difference: the energy use is the number that the design has already driven down. The steps are:
- Estimate annual energy use for the finished home, from an energy model, in kWh. An energy advisor or designer produces this.
- Divide by the annual output of one kilowatt of panels at the site. In much of Canada that is roughly 1,000 to 1,400 kWh, and a site-specific estimate gives a better figure.
- Check that the roof has enough usable, unshaded area facing south, east or west.
Worked example, with stated assumptions: an all-electric 2,000 square foot home with a heat pump, heat recovery ventilation and an airtight envelope uses about 10,000 kWh a year. At 1,200 kWh per kilowatt, the array size is about 8.3 kW. At 5 to 6 square metres of roof per kilowatt, that takes roughly 40 to 50 square metres, which fits on one good south plane or split between two. With an average shell, the same home might use double the energy and need 16 kW, probably more than the roof holds. The guide on roof space for solar panels shows the area arithmetic.
What mechanical systems go into a net zero home?
Almost all such homes in Canada are all-electric, because solar produces electricity and gas burned on site would count against the balance. A cold-climate air source unit usually supplies heating and cooling, and a heat pump water heater or a well-sized electric tank covers hot water. Ground source systems also appear where the lot allows. See heat pump sizing for cold climates and how solar panels and a heat pump work together.
Passive solar design can reduce winter loads further: south-facing glass sized for the climate, shading for summer, and thermal mass inside the thermal envelope. The passive solar design guide explains the rules. A passive house standard goes further on airtightness and insulation, and passive house in Canada compares it with net zero.
What does a net zero house cost, and what should you check?
Costs vary by region, year and design, and quotes decide. The envelope upgrades and the array are the main added items compared with a code-minimum home, partly offset by a smaller heating system and lower operating costs. The guide on net zero house cost in Canada lists the drivers.
Before committing, check these points:
- The utility's net metering terms and any cap on system size, because the annual balance depends on how exports are credited.
- Rebates and incentives for efficient new construction and for solar, which vary by province and change; the provincial energy ministry and the Government of Canada energy-efficiency pages hold the current terms.
- Whether the model uses real occupant loads, including appliances and an electric vehicle charger if you plan one.
- Roof orientation and shading from the start of design, since the array depends on both.
What did Drake Landing show about net zero heating?
Drake Landing took a different route to low-carbon heat. Its 52 homes were built to the R-2000 standard, a high-efficiency envelope, and were supplied with solar heat stored in the ground, as described on the DLSC homes page. The community reached a solar fraction of 97 per cent for space heating by 2012. The lesson is the same as for net zero: a tight envelope lowers demand, so a modest supply can meet it. Installation and operation costs matter too, and the guide linked below treats them. See what Drake Landing teaches about net zero heating.
Quick answers
How many solar panels does a net zero house need?
It depends on annual energy use. A very efficient 2,000 square foot all-electric home often needs an array of roughly 5 to 10 kW, which is about 12 to 25 panels at 400 watts.
Can a zero energy house keep a gas furnace?
Usually not, because gas used on site counts against the balance unless offset by extra generation. Most in cold climates use electric heat pumps instead.
Does a house like this still use the grid?
Yes. The home draws grid power at night and in winter and exports in summer. The label describes the yearly total, not independence from the grid.
Is net zero the same as passive house?
No. Net zero is an energy balance that includes generation, while passive house is a performance standard for the envelope. A home can meet both.
Where to verify
Programmes, rules and prices change. Before acting on anything you read here, check it at the source:
- Natural Resources Canada: federal energy-efficiency and clean-energy pages: programme status, EnerGuide labels, technical background.
- Your provincial electrical or building safety authority: permit, inspection and code requirements, including the edition of the Canadian Electrical Code in force.
- Canada Mortgage and Housing Corporation: housing research and guidance on building envelopes and ventilation.
- A licensed professional in your province: sizing, safety and installation for your particular building; these guides are general background only.