Ground-source heat and geothermal systems
Below a few metres, the ground holds a steady temperature that a ground-source heat pump can use all winter. These guides explain the loop designs, how deep boreholes work, and what affects installed cost and performance.
Last updated
About this topic
Below a few metres, the ground holds a steady temperature that a ground-source heat pump can use all winter. These guides explain the loop designs, how deep boreholes work, and what affects installed cost and performance.
Drake Landing used 144 boreholes about 35 metres deep as a heat store rather than a heat source, a close cousin of the same drilling technology. The related pages explain the difference.
All 32 guides on this topic
- Air-source and ground-source heat pumps compared: An air-source heat pump draws heat from outdoor air and costs less to install, while a ground-source heat pump draws it from buried loops and runs more efficiently, especially in deep cold. Ground source usually costs a multiple of air source up front, so the better choice depends on your site, budget and how long you will stay.
- Borehole fields: vertical ground heat exchangers: A borehole field is a set of vertical holes drilled into the ground, each holding a sealed loop of pipe, joined together so that fluid can carry heat into or out of the earth. Fields supply ground-source heat pumps and, in some projects, store summer heat for winter.
- Can a small or urban lot fit a geothermal loop?: Often yes. Vertical boreholes need only a small footprint, so a ground-source heat pump can work on a narrow city lot if the driller can reach it, the boreholes can be spaced safely and local rules allow it. The limit is usually access and spacing, not the amount of land.
- Can an older house switch to geothermal heating?: Yes, geothermal heating can be installed in an older home, and many existing houses have been converted. Whether it makes sense depends on how much heat the house loses, what distribution system it has, and whether a drilling rig can reach a suitable spot on the property.
- Choosing a Geothermal Drilling Contractor: Questions to Ask: A good geothermal drilling contractor is licensed for your province, insured, willing to put the loop design, grouting method and pressure testing in writing, and clear about who restores your yard. Ask for those items before you compare anything else.
- Do you need a permit to drill a geothermal loop?: Often yes, though the rules depend on the province, the municipality and the type of project. A home ground loop is usually handled through the contractor, the local building department and provincial drilling or well rules, while large power or district-scale geothermal projects sit under separate resource regulation.
- Estimating what a geothermal system could save you: Geothermal heat pump savings come from replacing a fuel or electric heater with a system that delivers several units of heat per unit of electricity. The size of the saving depends on three things you can look up: how much heat your house needs, what you pay for the fuel you use now, and the efficiency of the new system.
- Finding current rebates and loans for geothermal: Rebates for geothermal heat pumps in Canada come from federal, provincial and utility sources, and the terms change often, so this guide shows where to look rather than quoting amounts. Confirm every offer before signing a contract, because eligibility rules can depend on when you apply.
- Geothermal pump and ground loop: how they work together: A geothermal pump can mean two things: the heat pump that moves heat, or the small circulating pump that moves fluid through the buried loop. The circulating pump keeps antifreeze solution flowing between the ground and the heat pump, and its flow rate and fluid decide how well heat is exchanged.
- Ground heat or sun heat for your house?: Geothermal heating draws on stored warmth in the ground all year, while solar heating collects sunshine that is weakest in the weeks when a Canadian house needs it most. The two are complementary, and the Drake Landing project in Okotoks combined them by storing summer sun in the ground.
- Ground source heat pumps: the basics in plain words: A ground source heat pump uses the steady temperature of the earth as its heat source and sink, moving heat between the ground and the house with an electric compressor. Ground source, geothermal and geoexchange all describe the same residential technology, and the quotes you see will mix those terms freely.
- How a shared geothermal loop serves a neighbourhood: A community geothermal district system connects many buildings to a shared source of ground heat, usually a field of boreholes and a pipe network that distributes low-temperature fluid to heat pumps in each building. It spreads the cost of drilling and operation across users, but it needs an owner, a metering plan and a regulatory route.
- How deep and how close boreholes should go: Borehole depth sets how much pipe is in contact with the ground, and spacing sets how much neighbouring holes compete for the same heat. A house system keeps boreholes several metres apart, whereas the Drake Landing field packed 144 holes about 35 m deep at roughly 2.25 m spacing to store heat.
- How does geothermal heating work? A homeowner's view: Home geothermal heating takes low-grade heat from the ground through a buried loop and lifts it with a heat pump to a useful temperature for the house. The ground a few metres down stays near the yearly average air temperature, so the loop has a steadier heat source than outdoor air.
- How geothermal cooling works in summer: Geothermal cooling means running a ground-source heat pump in reverse: instead of pulling heat from the ground into the house, it moves heat out of the house and into the ground. The ground stays cooler than summer air, which is why the process uses less electricity than a typical air conditioner.
- How long does each part of a geothermal system last?: A geothermal heat pump has two parts with different lifespans. The indoor unit is mechanical and is commonly quoted at roughly two decades, while the buried ground loop is passive plastic pipe designed to last far longer, often half a century or more.
- How warm the earth stays beneath the surface: Below roughly 10 to 15 metres, ground temperature in Canada stays close to constant through the year and sits near the local average annual air temperature, often a few degrees above freezing in the south. Near the surface it swings with the seasons, which is why depth matters for heat pumps and storage.
- Inside a Borehole Heat Store: Borehole thermal energy storage (BTES) stores heat in the ground by circulating warm water through pipes in a field of drilled holes. The soil and rock around the holes hold the warmth for months.
- Installing a Geothermal Heat Pump: Step by Step: A geothermal heat pump installation usually runs through six stages: site survey, loop design, drilling or trenching, header and piping connection, indoor unit installation, and commissioning. The outdoor work often takes only a few days, but design and permits can take weeks before it starts.
- Is ground source heating right for your home?: Ground source heating suits homes that are well insulated, have a low-temperature way to spread heat and have room for a loop. Where those conditions are met, it can supply most of a house's heat at low running cost, and where they are not, the design needs extra work or a different system.
- Keeping a ground-source system in good shape: Geothermal heat pump maintenance is light: change the air filter, watch the loop pressure and the condensate drain, and book an annual check by a qualified technician. The buried loop usually needs no work, but its pressure and fluid should be confirmed.
- Loop field work on your property: what to expect: Loop field work is the outdoor part of a ground source heat pump installation, and it is usually the noisiest and messiest stage of the heat pump installation. For a house, drilling or trenching tends to take days, while the whole heat pump installation, with design, permits and commissioning, runs for weeks to a few months.
- Moving heat from the earth into your house: A ground-source heat pump circulates fluid through buried pipe to pick up ground heat, then uses a refrigerant cycle to raise that heat to a useful temperature for the house. It moves heat rather than making it, which is why it can deliver several units of heat for each unit of electricity.
- Parts of a geothermal HVAC system and what each does: A geothermal HVAC system provides heating and cooling for a home from five groups of parts: the underground loop, a circulating pump, the heat pump cabinet, the distribution inside the house and the controls. Knowing what each does makes quotes easier to read and problems easier to describe.
- Repairing or Replacing a Failed Geothermal Ground Loop: Geothermal ground loops are among the most durable parts of a ground-source heat pump system, and true loop failure is uncommon. When performance drops, the cause is far more often in the indoor unit, pump, controls or flow than in the buried pipe, so diagnosis comes before any digging.
- Testing the value of a geothermal system: A ground-source heat pump is worth it when the house stays put for many years, heating bills are high, the lot allows a loop and the upfront premium over alternatives is financeable. It is a poor fit for small loads, short stays or sites where drilling is difficult.
- The geothermal unit indoors: types, sizing and placement: The geothermal unit is the indoor cabinet that holds the compressor, the refrigerant circuit and the heat exchangers of a ground source system. It takes heat from the ground loop and passes it to the house as warm air or warm water, and in summer it runs in reverse for cooling.
- Trenches or boreholes for a ground loop: A horizontal ground loop uses shallow trenches and needs a lot of open land, while a vertical loop uses deep boreholes and needs little surface area but costs more per metre of access. The right choice usually comes down to lot size, soil, rock depth and what the contractor can reach.
- What a desuperheater does in a geothermal system: A desuperheater is a small heat exchanger on a ground-source heat pump that captures part of the compressor's hot refrigerant gas and uses it to heat domestic hot water. It only works while the heat pump is running, so it pre-heats water rather than replacing a water heater.
- What a ground-source system costs and why: A geothermal heat pump in Canada typically costs noticeably more up front than an air-source system, and the buried loop field is usually the biggest single reason. Final prices vary by region, soil, house size and year, so written quotes decide, not rules of thumb.
- What is a geothermal heat pump and who is it for?: A geothermal heat pump is an electric heating and cooling system that exchanges heat with the ground through a buried loop. It costs more to install than an air-source heat pump, and in return it offers steady performance in cold weather and lower running costs for houses that suit it.
- Why a geothermal heat pump stops working well: Most geothermal heat pump problems come from the indoor equipment, not the buried loop: a clogged filter, a thermostat or control fault, low airflow, a refrigerant leak or a worn compressor. Loop problems are rarer but costlier, so it pays to rule out the simple causes before calling for a loop diagnosis.
Where to verify
Programmes, rules and prices change. Before acting on anything you read here, check it at the source:
- Natural Resources Canada: federal energy-efficiency and clean-energy pages: programme status, EnerGuide labels, technical background.
- Your provincial or territorial energy ministry: current rebates, rules and programme intake dates.
- Provincial regulator for drilling and groundwater: licensing and rules that apply to boreholes and loop fields.
- A licensed professional in your province: sizing, safety and installation for your particular building; these guides are general background only.
dlsc.ca is an independent information site. It sells and installs nothing and gives no personal advice.