How a ground source heat pump system moves heat

A ground-source heat pump, also sold as a geothermal heat pump, circulates fluid through buried pipe to pick up ground heat, then uses a refrigerant cycle to raise that heat to a useful level for the building. It moves heat rather than making it, which is why it can deliver several units of heat for each unit of electricity.

Last updated

What are the main parts of a ground source heat pump system?

There are three loops in one system. The first is the ground loop: plastic pipe full of water or a water and antifreeze mix, laid in trenches or boreholes. The second is the refrigerant circuit inside the heat pump cabinet, with a compressor, an expansion valve and two heat exchangers. The third is the building's heat distribution, either ducted air or water running to floors or radiators.

A small circulation pump moves the fluid, and a controller decides when to heat, when to cool and how to handle domestic hot water. A closed loop keeps the same fluid circulating in sealed pipe. An open one draws groundwater from a well and returns it, which depends on water quality, supply and local approval; it is covered in the open-loop ground water guide. The names of each component and what to ask about them are in geothermal HVAC system parts.

How does the refrigerant cycle raise the temperature?

The refrigerant cycle moves the heat in four steps.

  1. Absorb. Fluid arrives at the heat pump a few degrees above freezing at the cold end of winter. In the first exchanger it warms a refrigerant that boils at a very low temperature, so the substance turns to gas even from that modest source.
  2. Compress. The compressor squeezes the gas, which raises its pressure and temperature sharply.
  3. Release. In the second heat exchanger the hot gas gives its heat to the water or air of the heating system and condenses back to liquid.
  4. Expand. The expansion valve drops the pressure, the refrigerant cools, and the sequence repeats.

The compressor is the main electrical load. Everything else is moving heat that was already there. Handling the charge is work for certified technicians, since the sealed circuit is pressurised and regulated.

What is COP and why does it matter?

Coefficient of performance, or COP, is heat delivered divided by electricity used. A COP of 4 means one kilowatt-hour of electricity delivers four kilowatt-hours of heat, with three of those drawn from the ground. Ground-source units are often quoted somewhere between 3 and 5 depending on test conditions, and the rating comes from a laboratory test standard, so read which conditions the number applies to. The figure you live with is the seasonal average, and it depends on how hot the water or air has to be. The wider topic of ratings is in the COP explainer.

Lower supply temperatures raise the result. That is why underfloor heating and large radiators pair well with ground-source units; see low temperature hydronic heating for the reasoning. Anything below 1 would be worse than a baseboard heater, and a heat pump is nowhere near that range in normal use. Energy efficiency over the long term also depends on loop size, flow rate and how the system is controlled.

How does a ground source system switch to cooling?

A reversing valve changes the direction of the refrigerant flow. In summer the heat pump takes heat out of the indoor air or water and sends it into the ground, which becomes the place where heat is rejected. Many models can also divert some of that heat to the hot water tank. Cooling is a separate topic, and geothermal cooling in Canada covers it. Check that the model and distribution you choose support cooling, because radiant floors need controls that avoid condensation.

Why the ground, and not the air?

Winter air in much of Canada can drop far below the warmth of soil a few metres down. Cold air gives an air-source heat pump less to work with just when demand peaks, while the ground changes slowly. How stable the soil is, and at what depth, is explained in ground temperature by depth in Canada. The trade is that the ground loop costs money, as the cost guide lays out, and the full side-by-side is in air source vs ground source heat pumps.

What affects performance and installation?

Heat pump installation on the ground side is a planning task before it is a digging task. The designer needs the heating and cooling load of the building, the type of soil or rock, the depth of the water table and the space available. These set the type and length of the field, and the choices are compared in horizontal and vertical ground loops.

  • Soil and rock. Moist soil and solid rock move heat better than dry sand.
  • Loop length. A loop sized with margin keeps the fluid warmer and the system more efficient.
  • Distribution. Cooler water or air raises efficiency.
  • Controls and flow. A pump that moves too much fluid wastes energy.
  • Workmanship. Fusion-welded joints, pressure tests and flushing protect the system for decades.

Installing a ground source system requires licensed professionals for drilling, pipe work, refrigerant and electrical connections. Provincial groundwater or environment rules, municipal permits and the electrical safety authority differ by region, so ask the installer which approvals apply. The order of work is laid out in the installation process.

What are the benefits and limits of the thermal source?

One heat pump system can provide space heating, cooling and, with a desuperheater, part of the hot water. Operating cost is mostly the power for the compressor and pumps, and the thermal source is the same all year, so the result changes little with the weather. The limits are the upfront cost, the land or drilling access and the need for a competent design.

Designers also check the heat balance of the ground. A building that draws far more heat than it returns can cool the soil slowly over many years, and one dominated by cooling can warm it. A loop with enough length keeps the change small, which is why the predicted fluid temperature over several years is worth asking for. Energy that a heat pump moves is not free of limits, but the operating pattern is predictable once the field is sized correctly.

Where does Drake Landing fit in?

Drake Landing did not use ground-source heat pumps. It used buried pipe for storage instead: 144 boreholes about 35 to 37 m deep held heat gathered by 800 solar collectors over summer, and a district loop delivered it to 52 homes. The ground acted as a battery rather than a continuing source. How that differs from using the ground continuously is covered in geothermal vs solar heating.

A worked example with stated assumptions

Suppose a building needs 12,000 kWh of heat over a winter, and the system averages a COP of 4 over that period. The compressor and pumps would draw about 3,000 kWh of power, and roughly 9,000 kWh would come from the ground. If the same building used a resistance heater at a ratio of 1, it would draw all 12,000 kWh. The numbers are round assumptions for illustration only; real seasonal values depend on the equipment, the fluid temperatures and the supply temperature of the heating system.

The comparison also explains why a heat pump is judged on efficiency at design conditions. A system that meets the coldest day through a well-sized loop holds its figure better than one forced to lean on electric backup elements. Related reading on cold-weather behaviour is in the cold climate heat pump guide.

Quick answers

Does a ground source heat pump make heat or move it?

It moves heat. Most of the delivered energy comes from the ground, and the electricity runs the compressor and pumps.

What does COP mean on a heat pump?

COP is the heat delivered per unit of electricity consumed. A COP of 4 means four units of heat for each unit of power.

Can a ground source heat pump also cool a building?

Many can, by reversing the cycle and rejecting indoor heat into the ground loop. Check that the model and distribution system you choose support cooling.

Do ground source heat pumps work in very cold weather?

Yes, because the soil warms and cools far more slowly than the air. The loop is designed for the coldest design conditions, so the equipment is sized with that load in mind.

Where to verify

Programmes, rules and prices change. Before acting on anything you read here, check it at the source:

  • Natural Resources Canada: federal energy-efficiency and clean-energy pages: programme status, EnerGuide labels, technical background.
  • Your provincial or territorial energy ministry: current rebates, rules and programme intake dates.
  • Provincial regulator for drilling and groundwater: licensing and rules that apply to boreholes and loop fields.
  • A licensed professional in your province: sizing, safety and installation for your particular building; these guides are general background only.

dlsc.ca is an independent information site. It sells and installs nothing and gives no personal advice.

Part of the topic: Ground-source and geothermal heat. See all guides on this topic.